Energy KPI · HVAC-only benchmark

Generated data

HVAC-only benchmark and room-level allocation

July electricity of the installed split and cassette systems, compared apples-to-apples with HVAC-only literature benchmarks. Domestic hot water is excluded and tracked separately.

Illustrative data. Figures on this page follow the benchmark specification but the daily series and room allocation are generated/modeled from design cooling-load shares. They are not room submetering and will be replaced by live telemetry.
1,805 kWh
July HVAC electricity
€472 @ €0.2612/kWh
58.2 kWh/day
HVAC daily run-rate
July forecast basis
3,138 kWh
Main breaker total
€820 July forecast
57.5%
HVAC share
HVAC only / total electricity
235 kWh
DHW excluded
7.5% shown separately
35–50%
Benchmark band
typical HVAC share

HVAC share vs. benchmark band

0%Efficient <35%Typical 35–50%High >50%100%

At 57.5% the building sits above the typical annual band in July. Treat this as a summer cooling-peak signal, not an annual failure, until full-year metering and cooling-degree-day normalization are available.

Daily HVAC kWh — July

Generated data
1 Julavg 58.2 kWh/day31 Jul

HVAC intensity by conditioned area

The final conditioned floor area is still to be confirmed. Move the slider to see the resulting kWh/m²-month.

5.16
kWh/m²-month (July)
Moderate

Allocation by floor

Basement7.4 kW · 448 kWh · €117 · 24.8%
Ground12.3 kW · 745 kWh · €195 · 41.3%
Upper10.1 kW · 612 kWh · €160 · 33.9%

Top energy rooms

Generated data
  • Living and dining room
    309
  • Kitchen and breakfast area
    182
  • Lounge
    170
  • Game room
    164
  • Bedroom 2 lounge
    127
  • Office
    109
  • Guest bedroom 2
    73
  • Workshop / crafts room
    55
  • Guest bedroom zone
    55
  • Guest bedroom 1
    55
  • Bedroom 2
    55
  • Bedroom 1 / en-suite
    55

Room table — July baseline

Generated data
IDRoom / zoneArea m²Load kWShare %July kWh€/JulkWh/dkWh/m²-moClass
G1Living and dining room
main occupied zone
63.05.117.1309.080.79.974.90Moderate
G2Kitchen and breakfast area
appliance load
29.73.010.1181.747.55.866.12High
B4Lounge
dedicated split support
49.82.89.4169.644.35.473.41Low
B3Game room
Mitsubishi Kirigamine Zen
47.22.79.1163.642.75.283.47Low
U11Bedroom 2 lounge
Venice zone lounge
26.12.17.0127.233.24.104.87Moderate
G9Office
Daikin Emura / work load
23.31.86.0109.028.53.524.68Moderate
U6Guest bedroom 2
Samsung WindFree cassette
14.41.24.072.719.02.355.05Moderate
B2Workshop / crafts room
earth-contact space
19.30.93.054.514.21.762.82Low
U4Guest bedroom zone
Samsung WindFree guest zone
10.60.93.054.514.21.765.14Moderate
U5Guest bedroom 1
Samsung WindFree cassette
11.10.93.054.514.21.764.91Moderate
U8Bedroom 2
Venice zone
11.40.93.054.514.21.764.78Moderate
U13Bedroom 1 / en-suite
Honolulu zone
11.90.93.054.514.21.764.58Moderate
U1Upper-floor corridor
circulation below roof
15.30.82.748.512.71.563.17Low
G4Service bedroom
Samsung WindFree cassette
10.30.72.342.411.11.374.12Moderate
G7Entrance hall
roof/hall support
14.80.72.342.411.11.372.87Low
U10Bedroom 2 bathroom / ancillary
Venice ancillary
16.40.72.342.411.11.372.59Low
G8Ground-floor corridor
tempered circulation
10.80.51.730.37.90.982.80Low
U9Bedroom 2 dressing / ancillary
Venice ancillary
10.70.51.730.37.90.982.83Low
B1Gym
occupancy load when used
8.00.41.324.26.30.783.03Low
U2Guest corridor
guest circulation
8.30.41.324.26.30.782.92Low
B5Vestibule / corridor / storage
tempered circulation
9.10.31.018.24.70.592.00Low
U3Guest / upper-floor bathroom
wet room
7.00.31.018.24.70.592.60Low
U12Bedroom 1 dressing room
Honolulu ancillary
6.20.31.018.24.70.592.93Low
B7Storage room
optional cooling
10.40.20.712.13.20.391.17Low
G3Laundry
utility room
4.00.20.712.13.20.393.03Low
U7Upper-floor bathroom
wet room
6.60.20.712.13.20.391.84Low
B6WC
small wet room
4.50.10.36.11.60.201.35Low
G5Service bathroom
wet room
4.30.10.36.11.60.201.41Low
G6Ground-floor WC
wet room
4.20.10.36.11.60.201.44Low
G10Pantry / cloakroom / ancillary
minor ancillary
2.40.10.36.11.60.202.52Low
B8Garage
not actively cooled
97.50.00.00.00.00.000.00Excluded
G11Porches
not cooled
41.50.00.00.00.00.000.00Excluded
U14Open terrace
not cooled
66.60.00.00.00.00.000.00Excluded

Intensity classes: Low ≤4.0 · Moderate 4.0–6.0 · High 6.0–8.0 · Critical >8.0 kWh/m²-month

Method

  1. Aggregate HVAC. €471.54 / €0.2612 per kWh = 1,805.3 kWh. Only HVAC electricity; DHW, EV, kitchen, lighting, pumps excluded.
  2. Room share. Room design cooling load / cooled-room total (29.8 kW).
  3. Room kWh. 1,805.3 kWh × room share.
  4. Room intensity. Room kWh / room floor area.
  5. Normalize. HVAC share → kWh/m²-month → kWh/m²/CDD → kWh per occupied room-night.

Next inputs: confirmed conditioned area, occupied room-nights, local cooling degree days, and live per-room compressor duty cycle, damper runtime, occupancy and comfort feedback.

Benchmark sources